LaserGasTM II Open Path Monitor

LaserGasTM II Open Path Monitor

 

Open Path

 

The Open Path Monitor is designed for long distance monitoring in ambient air, monitoring in production halls, and gas leak detection. Measurement lengths of up to 1000 m one way are possible.

The monitor comprises the transceiver unit with laser, detector and all electronic boards and the retro-reflector unit. The passive retro-reflector located opposite to the laser reflects the light back to the transceiver. The detector collects the returned light for further analysis and calculation of the gas concentration.

 

The LaserGas II OP has environmental protection IP 66 and is suitable for rough industrial environments and outdoor use.

The monitor is installed on our proprietary x/y alignment platform (goniometer). Adapters for fixed installation on platforms or for tripod use are available. The instrument also includes a visible aiming laser and sighting optics for easy alignment even over long distances.

Hoods for protection of the optical windows on transceiver and reflector side can be supplied. In rough industrial environments it is advisable to blow these windows with a fan to prevent dust deposition.

 

Measurement readings are provided through standard 4-20 mA current loops, or as options the fibre-optic output and the Ethernet interface. The latter enables instrument communication via local area networks or the Internet.

As option a portable, battery-powered version of the LaserGas II OP is available containing control keypad and flash memory for data logging.

Based on the well-proven tuneable diode laser (TDLAS) technology the instrument has a number of unique features.

 

Features

  • Up to 1000 m measurement path
  • Zero cross interference from moisture (or other gases)
  • Unaffected by fog or rain down to <1% transmission
  • Low cost of ownership
  • Suitable for ATEX zone 1 (EEx p) and zone 2 (EEx n)
  • Suitable for CSA Class 1 Div 2 (non incendive)

 

Table of Principal Gases

Gas

Detection limit [ppb]

NH3

10

HCl

5

HF

1

H2S

200

CO

30

N2O

150

CH4

10

 

NOTE: Detection limits are specified for 100 m optical path (one way) and gas temperature / pressure = 25 °C / 1 bar abs.
Also available are CO2, HCN, C2H2, C2H4, C3H6, CH3I, CH2O, CH2CHCl (VCM), C2H4O (EtO), CH2Cl2 (DCM)
Dual Gas: NH3+H2O, HCl+H2O, HF+H2O, CO+H2O, CH4+CO2

Documentatie

LaserGas II Open Path. (2008) (Acrobat 181183 byte Download: LaserGas II Open Path. (2008) (Acrobat 181183 bytes)(.pdf)
LaserGas II OP data sheet (310 kB) Download: LaserGas II OP data sheet (310 kB)
LaserGas II OP ATEX version (500 kB) Download: LaserGas II OP ATEX version (500 kB)